Introduction edit

Capacitive deionization (CDI) is a technology to deionize water by applying an electrical potential difference over two porous carbon electrodes. Anions, ions with a negative charge, are removed from the water and are stored in the positively polarized electrode. Likewise, cations (positive charge) are stored in the cathode, which is the negatively polarized electrode.

Today, CDI is mainly used for the desalination of brackish water, which is water with a low or moderate salt concentration (below 10 g/L) [1][2] . Other technologies for the deionization of water are, amongst others, distillation, reverse-osmosis and electro dialysis. Compared to these other technologies, CDI is considered to be an energy-efficient technology for brackish water [2]. This is mainly because CDI removes the salt ions from the water, while the other technologies extract the water from the salt solution [1].

Historically, CDI has been referred to as electrochemical demineralization, electrosorb processes for desalination of water, or electrosorption of salt ions.

History edit

In 1960 a conceptual study was performed on electrochemical demineralization of water by Blair and Murphy[3]. In that study, it was assumed that ions were removed by electrochemical reactions with specific chemical groups on the carbon particles in the electrodes. Although, at that time, the exact principles for ion storage in the electrodes remained speculative, in 1968 the commercial relevance and the long term operation was demonstrated by Reid [4] . In 1970 Johnson et al.[5] introduced a theory for the CDI process called ‘potential modulated ion sorption’; the latter is today more commonly known as the Electric Double Layer (EDL) theory. With little research carried out between 1978 and 1995, in the period thereafter CDI attracted more attention because of the development of new electrode materials, such as carbon aerogels or carbon nanotube electrodes[6] . Furthermore, Farmer et al.[6] introduced the term capacitive deionization and used the now commonly abbreviation “CDI” for the first time.

Process edit

Adsorption and desorption cycles edit

The operation of a conventional CDI system cycles through two phases: an adsorption phase where water is desalinated and a desorption phase where the electrodes are regenerated. During the adsorption phase, a potential difference over two electrodes is applied and ions are adsorbed from the water. The ions are transported through the interparticle pores of the porous carbon electrode to the intraparticle pores, where the ions are electrosorbed in the so-called electrical double layers (EDLs). After the electrodes are saturated with ions, the adsorbed ions are released for regeneration of the electrodes. The potential difference between electrodes is reversed or reduced to zero. In this way, ions leave the electrode pores and can be flushed out of the CDI cell resulting in an effluent stream with a high salt concentration, the so-called brine stream or concentrate. Part of the energy input required during the adsorption phase can be recovered during this desorption step.

 
Adsorption of ions from the brackish water to regenerate the electrodes (Figure adapted from [1] )
 
Desorption of ions from the brackish water to regenerate the electrodes (Figure adapted from [1] )

Ion adsorption in Electrical Double Layers edit

Any amount of charge should always be compensated by the same amount of counter-charge. For example, in an aqueous solution the concentration of the anions equals the concentration of cations. However, in the EDLs formed in the intraparticle pores, an excess of one type of ion over the other is possible, but it has to be compensated by electrical charge in the carbon matrix. In a first approximation, this EDL can be described using the Gouy-Chapman-Stern model, which distinguishes three different layers [7]  ; [8] ; [9] ; [10] ):

  • The porous carbon matrix, which contains the electrical charge on the surface of the carbon particles.
  • A Stern layer is located between the carbon matrix and the diffuse layer. The Stern-layer is a dielectric layer, i.e. it separates two layers with charge, but it does not carry any charge itself.
  • The diffuse layer, in which the ions compensate the electrical charge of the carbon matrix. The ions are diffusively distributed in this layer. The width of the diffuse layer can often be approximated using the Debye length, characterizing that the concentration of counter-ions decays by a factor e. To illustrate this, the Debye length is about 3.1 nm at 20 °C and for a 10 mM NaCl solution. This implies that more than 95% of the electrical charge in the carbon matrix is compensated in a diffuse layer with a width of 9.3 nm.

As the carbon matrix is charged, the charge has to be compensated by ionic charge in the diffuse layer. This can be done by either the adsorption of counterions, or the desorption of co-ions (ions with an equal charge sign as the one in the carbon matrix).

 
Electrical Double Layer (model according to the Gouy-Chapman-Stern theory)

Besides the adsorption of ionic species due to the formation of EDLs in the intraparticle pores, ions can form a chemical bond with the surface area of the carbon particles as well. This is called specific adsorption, whilst the adsorption of ions in the EDLs is referred to as non-specific adsorption[11] .

Membrane capacitive deionization edit

By inserting two ion exchange membranes, a modified form of CDI is obtained, namely Membrane Capacitive Deionization (MCDI). This modification improves the CDI cell in several ways:

  • Co-ions do not leave the electrodes during the adsorption phase, as described above (see Ion adsorption in Electrical Double Layers for explanation). Instead, due to the inclusion of the ion exchange membranes, these co-ions will be kept in the interparticle pores of the electrodes, which enhances the salt adsorption efficiency [12] [13] [14].
  • Since these co-ions cannot leave the electrodes and because the electroneutrality condition applies for the interparticle pores, extra counter-ions must pass through the ion-exchange membranes, which gives rise to the salt adsorption efficiency as well [12] [13][14].
  • Operating MCDI at constant current mode can produce freshwater with a stable effluent concentration (see constant voltage vs. constant current for more information).
  • The required energy input of MCDI is lower than of CDI [15] [12] [13][14].
 
Capacitive deionization during the adsorption cycle (Figure adapted from [1] )
 
Membrane capacitive deionization during the adsorption cycle (Figure adapted from [1] )

Constant voltage vs. constant current operation mode edit

A CDI cell can be operated in either the constant voltage or the constant current mode. The difference between the two modes reflects that the way in which charge is transported to the electrodes play an important role in the CDI operation.

Constant voltage operation edit

During the adsorption phase of a constant voltage operation, the salt effluent salt concentration decreases, but after a while, the effluent salt concentration increases again. This can be explained because the EDLs are uncharged at the beginning of an adsorption step, which results in a high potential difference (electrical driving force on the ions) over the two electrodes. When more ions are adsorbed in the EDLs, the EDL potential increases and the remaining potential difference between the electrodes, which drives the ion transport, decreases. Because of the decreasing ion removal rate, the effluent concentration increases again [16].

Constant current operation edit

Since the ionic charge transported into the electrodes is equal to the applied electrical current, applying a constant current allows a better control on the effluent salt concentration compared to the constant voltage operation mode. However, for a stable effluent salt concentration membranes should be incorporated in the cell design (MCDI), as the electrical current does not only induce counter-ion adsorption, but co-ion depletion as well (see Membrane capacitive deionization vs. Capacitive deionization for an explanation) [17].

Cell geometries edit

Flow-by mode edit

The electrodes are placed in a stack with a thin spacer area in between, through which the water flows. This is by far the most commonly used mode of operation and electrodes prepared in a similar fashion as for electrical double layer capacitors with a high carbon mass loading can be used.

Flow-through mode edit

The feed water flows straight through the electrodes, i.e. the water flows directly through the interparticle pores of the porous carbon electrodes. This approach has the benefit of ions directly migrating through these pores, hence mitigating transport limitations encountered in the flow-by mode [18] .

Flow-electrode capacitive deionization edit

This geometrical design is comparable to the flow-by mode with the inclusion of membranes in front of both electrodes, but instead of having solid electrodes, a carbon suspension (slurry) flows between the membranes and the current collector. A potential difference is applied between both channels of flowing carbon slurries, the so-called flow electrodes, and water is desalinated. Since the carbon slurries flow, the electrodes do not saturate and therefore this cell design can be used for the desalination of water with high salt concentrations as well (e.g. sea water, with salt concentrations of approximately 30 g/L). A discharging step is not necessary; the carbon slurries are, after leaving the cell, mixed together and the carbon slurry can be separated from a concentrated salt water stream [19].

 
Flow-through CDI cell during the adsorption cycle
 
Flow-electrode CDI cell during the adsorption cycle

Electrode materials edit

For a high performance of the CDI cell, high quality electrode materials are of utmost importance. Carbon is the choice as porous electrode material. Regarding the structure of the carbon material, there are several considerations. As a high salt electrosorption capacity is important, the specific surface area and the pore size distribution of the carbon accessible for ions should be large. Furthermore, the used material should be stable and no chemical degradation of the electrode (degradation) should occur in the voltage window applied for CDI. The ions should be able to move fast through the pore network of the carbon and the conductivity of the carbon should be high. Lastly, the costs of the electrode materials are important to take into consideration [20] .

Nowadays, activated carbon (AC) is the commonly used material, as it is the most cost efficient option and it has a high specific surface area. It can be made from natural or synthetic sources. Other carbon materials used in CDI research are, for example, ordered mesoporous carbon, carbon aerogels (Research), carbide-derived carbons, carbon nanotubes, graphene and carbon black [1] .


Energy requirements edit

Since the ionic content of water is demixed during a CDI adsorption cycle, the entropy of the system decreases and an external energy input is required. The theoretical energy input of CDI can be calculated as follows:

 

where R is the gas constant (8.314 J mol-1 K-1), T the temperature (K), Φv,fresh, the flow rate of the fresh water outflow (m3/s), Cfeed the concentration of ions in the feed water (mol/m3) and Cfresh the ion concentration in the fresh water outflow (mol/m3) of the CDI cell. α is defined Cfeed/Cfresh and β as Cfeed/Cconc, with Cconc the concentration of the ions in the concentrated outflow.

In practice, the energy requirements will be significantly higher than the theoretical energy input. Important energy requirements, which are not included in the theoretical energy requirements, are pumping, and losses in the CDI cell due to internal resistances. If MCDI and CDI are compared on the energy required per removed ion, MCDI shows to have lower energy requirements than CDI. Comparing the constant current and constant voltage operation, constant current is characterized with lower energy requirements [16]

Comparing CDI with reverse osmosis of water with salt concentrations lower than 30 mM, lab-scale research shows that the energy consumption in kWh per m3 freshwater produced are lower for MCDI than for reverse osmosis [16] [1] .

Large-scale CDI facilities edit

In 2007, a 10,000 tons per day full-scale CDI plant was built in China for improving the reclaimed water quality by ESTPURE[21] . This project enables the reduction of total dissolved solids from 1,000 mg/L to 250 mg/L and turbidity from 10 NTU to 1 NTU, a unit indicating the cloudiness of a fluid. The water recovery can reach 75%. Electrical energy consumption level is 1 kWh/m3, and the cost for water treatment is 0.22 US dollars/m3. Some other large-scale projects can be seen from the table below.

Water source Purpose Scale (m3/d Water recovery rate Salt removal rate Energy consumption (kWh/t produced water) Reference
Municipal wastewater being treated by first and second order processes + circulating water Circulating water Example 10000 75% 75% [22]
Cooling water Circulating water 120000 75% 85% of Cl- 0.75 [23]
Wastewater Circulating water 2400 75% ≥50% 1.33 [21]

References edit

  1. ^ a b c d e f g h Porada, S. (2013). "Review on the science and Technology of Water Desalination by Capacitive Deionization". Review on the Science and Technology of Water Desalination by Capacitive Deionization. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  2. ^ a b Anderson, M.A. (2010). "Capacitive deionization as an electrochemical means of saving energy and delivering clean water. Comparing to present desalination practices: Will it compete?". Electrochimica Acta. 55 (12): 3845–3856. doi:10.1016/j.electacta.2010.02.012. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  3. ^ Blair, J.W. (1960). "Electrochemical demineralization of Water with Porous Carbon Electrodes of Large Surface Area". Saline Water Conversion. 27. doi:10.1021/ba-1960-0027.ch020. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  4. ^ Reid, G.W. (1968). "Field operation of a 20 gallons per day pilot plant unit for electrochemical desalination of brackish water". Washington D.C.: U.S. Dept. of the Interior. {{cite journal}}: Cite journal requires |journal= (help)
  5. ^ Johnson, A.M. (1970). The Electrosorb Processes for Desalting Water. {{cite journal}}: Missing or empty |title= (help); Unknown parameter |coauthors= ignored (|author= suggested) (help)
  6. ^ a b Farmer, J.C. (1996). "Capacitive deionization of NaCl and NaNO3 solutions with carbon aerogel electrodes". Journal of the Electrochemical Society. 143 (1): 159–169. doi:10.1149/1.1836402. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  7. ^ Kirby, B.J. "The diffuse structure of the electrical double layer".
  8. ^ "Britannica - Electrical Double Layer".
  9. ^ "TDA Research - Capacitive deionization".
  10. ^ Limpt, B. (2010). Performance relations in Capacitive Deionization systems.
  11. ^ Ibach, H. (2006). Physics of Surfaces and Interfaces. Springer-Verlag.
  12. ^ a b c Li, H. (2008). "Electrosorptive desalination by carbon nanotubes and nanofibres electrodes and ion-exchange membranes". Water Researcg. 42 (20). {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  13. ^ a b c Kim, Y. (2010). "Enhanced desalination efficiency in capacitive deionization with an ion-selective membrane". Separation and Purification Technology. 71 (1): 70–75. doi:10.1016/j.seppur.2009.10.026. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  14. ^ a b c Zhao, R. (2012). "Time-dependent ion selectivity in capacitive charging of porous electrodes". Journal of Colloid and Interface Science. 384 (1): 38–44. doi:10.1016/j.jcis.2012.06.022. hdl:1721.1/101160. PMID 22819395. S2CID 12916467. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  15. ^ Lee, J.B. (2006). "Desalination of a thermal power plant wastewater by membrane capacitive deionization". Desalination. 196 (1): 125–134. doi:10.1016/j.desal.2006.01.011. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  16. ^ a b c Zhao, R. (2012). "Energy consumption and constant current operation in membrane capacitive deionization". Energy & Environmental Science. 5 (11): 9520–9527. doi:10.1039/c2ee21737f. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  17. ^ Zhao, R. (2012). "Energy consumption and constant current operation in membrane capacitive deionization". Energy & Environmental Science. 5 (11): 9520–9527. doi:10.1039/c2ee21737f. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  18. ^ Suss, M.E. (2012). "Capacitive desalination with flow-through electrodes". Energy & Environmental Science. 5 (11): 9511–9519. doi:10.1039/c2ee21498a. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  19. ^ Jeon, S. (2013). "Desalination via a new membrane capacitive deionization process utilizing flow-electrodes". Energy & Environmental Science. 6 (5): 1471–1475. doi:10.1039/c3ee24443a. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  20. ^ Oren, Y. (2008). "Capacitive deionization (CDI) for desalination and water treatment — past, present and future (a review)". Desalination. 228 (1): 10–29. doi:10.1016/j.desal.2007.08.005.
  21. ^ a b ESPURE. "A chemical wastewater reuse and quality promotion project in Shanxi".
  22. ^ ESTPURE. "Inner Mongolia power group water recycling project".
  23. ^ ESTPURE. "A water reclaimed water plant upgrade project in Ningbo, Zhejiang".