Can anyone please give a brief explanation of how a sample is measured? The plasma-to-ms in the intro is too brief, and the full explanation too lengthy. —Preceding unsigned comment added by 192.38.9.39 (talk) 09:20, 29 June 2010 (UTC)Reply

A sample is prepared in liquid form. A flow of gas, applied to the sample, converts the sample to an aerosol form. A plasma torch is then applied to the aerosol which ionizes the atoms. Mass spectrometry is then performed on the ionized atoms. Thintommy 14:02, 21 September 2015 (UTC)Reply

Question edit

Does the sample being measured have to be in liquid form? So if a sample fo a metal alloy was being measured would it have to be dissolved in acid first? Thanks. OAP boba 08:18, 24 November 2006 (UTC)Reply

Samples are normally liquids. Solids can generally be dissolved in acids or by other means to produce liquids. However solids can be analyzed directly by laser ablation. A pulsed laser, diected at the surface of the solid, produces a plume of material which is then carried into the plasma to produce ions.
...or an electrically conductive solid can be introduced by spark erosion. Weasley one (talk) 11:25, 23 December 2011 (UTC)Reply

Dynamic Reaction Cell edit

The DRC page has been tagged as needing a clean-up for some time. Anybody over here want to give it a shot?--SteveMtl 15:43, 3 May 2007 (UTC)Reply

Merge dynamic reaction cell with ICP-MS edit

Dynamic Reaction Cell is a related short article with cleanup needs. A merge could help set that information with the context of this article. Comments? --Kkmurray 02:17, 16 June 2007 (UTC)Reply

Merged, but article still needs refs and cleanup.--Kkmurray 17:44, 27 June 2007 (UTC)Reply

Rename (de-Acronym) edit

See WP:NAME and WP:ACRONYM. The main issue is whether ICP-MS is "almost exclusively known only by its acronym" (emphasis added). I am arguing that it is known by both so the acronym should be spelled out. This will essentially be a swap of redirect and content between the existing ICP-MS and Inductively coupled plasma mass spectrometry. --Kkmurray 04:13, 29 August 2007 (UTC)Reply

Requested move edit

Request is here: WP:RM —Preceding unsigned comment added by Kkmurray (talkcontribs) 04:42, 31 August 2007 (UTC)Reply

Additional rationale: ICP disambiguates to article Inductively coupled plasma, ICP-AES redirects to Inductively coupled plasma atomic emission spectroscopy. In this scheme, ICP-MS should redirect (remembering to sign this time). --Kkmurray 13:50, 31 August 2007 (UTC)Reply

This article has been renamed from ICP-MS to Inductively coupled plasma mass spectrometry as the result of a move request. --Stemonitis 07:50, 5 September 2007 (UTC)Reply

It is also of importance to notify that there are other types of detectors conected to the ICP, that is not metioned here. Like the SFMS and other. —Preceding unsigned comment added by 213.88.172.186 (talk) 14:11, 12 June 2008 (UTC)Reply

WikiProject class rating edit

This article was automatically assessed because at least one WikiProject had rated the article as start, and the rating on other projects was brought up to start class. BetacommandBot 09:54, 10 November 2007 (UTC)Reply

Info about the tech of ICP-AES.... edit

--222.64.223.221 (talk) 12:25, 20 June 2010 (UTC)Reply

--222.64.223.221 (talk) 12:27, 20 June 2010 (UTC)Reply

Accuracy and precision edit

--222.64.223.221 (talk) 12:29, 20 June 2010 (UTC)Reply

--222.64.223.221 (talk) 12:36, 20 June 2010 (UTC)Reply

Selectivity/specificity edit

--222.64.223.221 (talk) 12:34, 20 June 2010 (UTC)Reply

Limit of detection edit

--222.64.223.221 (talk) 12:39, 20 June 2010 (UTC)Reply

Linearity edit

--222.64.223.221 (talk) 12:41, 20 June 2010 (UTC)Reply

Hopefully, I can see the monograph about the linearity, reproducibility and Limit of quantification for the tech in the future to demonstrate the soundness, if the tech is not at the preliminary stage.

To be honest, curve fitting techs other than linear one is rarely used in Analytical chemistry

Hope my above search results are objective ones rather than subjectively-chasing events. I mean that analytical chemists prefer demonstrating the linearities of the teches in the field to other curve fittings

Please bear in mind that the subject of curve fitting in the topic of Verification and validation applies to any fields. --222.64.223.221 (talk) 13:18, 20 June 2010 (UTC)Reply

The history edit

From Google scholar

I'm surprised that the tech has got a such long history and not many monographs about its linearity which usually should be assessed even at the preliminary stage --222.67.209.251 (talk) 13:49, 20 June 2010 (UTC)Reply

Although no monographs about its linearity but the following infos give glimps

--222.67.209.251 (talk) 14:04, 20 June 2010 (UTC)Reply

Validity edit

--222.64.19.136 (talk) 14:14, 20 June 2010 (UTC)Reply

--222.64.19.136 (talk) 14:16, 20 June 2010 (UTC)Reply

--222.64.19.136 (talk) 14:17, 20 June 2010 (UTC)Reply

--222.64.19.136 (talk) 14:26, 20 June 2010 (UTC)Reply

--222.64.19.136 (talk) 14:28, 20 June 2010 (UTC)Reply

Nomenclature problem...??? edit

--222.64.19.136 (talk) 14:23, 20 June 2010 (UTC)Reply

About the definition of..... edit

--222.64.19.136 (talk) 14:33, 20 June 2010 (UTC)Reply

--222.64.19.136 (talk) 14:35, 20 June 2010 (UTC)Reply

--222.64.19.136 (talk) 14:36, 20 June 2010 (UTC)Reply

--222.64.19.136 (talk) 14:37, 20 June 2010 (UTC)Reply

Public opinion edit

--222.64.19.136 (talk) 14:46, 20 June 2010 (UTC)Reply

Science & religion ..... edit

related.....?????

--222.64.213.93 (talk) 00:10, 21 June 2010 (UTC)Reply

Since Karmapa has been considered as a Kuanyin's manifestation on the earth [citation needed] and Kuanyin really is the Godess of earth which is a female figure. I don't know what to say.....because the above consequence happened on the earth though --222.64.213.93 (talk) 00:02, 21 June 2010 (UTC)Reply

--222.64.223.89 (talk) 01:33, 21 June 2010 (UTC)Reply

--222.64.223.89 (talk) 01:30, 21 June 2010 (UTC)Reply

--222.64.213.93 (talk) 00:09, 21 June 2010 (UTC)Reply

--222.64.213.93 (talk) 00:13, 21 June 2010 (UTC)Reply

--222.64.213.93 (talk) 00:16, 21 June 2010 (UTC)Reply

I'll see how the spirit of the sixteenth karmapa sort this mess....@__@ --222.64.223.89 (talk) 01:38, 21 June 2010 (UTC)Reply

'Nomenclature'? edit

What information exactly or information along what lines is supposed to go there? Is it about "quadrupole" vs. "high-resolution"? Is it about interferences issues? "Cold"/"hot" plasma modes? I don't quite get the idea of the planned section. 213.171.63.227 (talk) 11:16, 2 February 2011 (UTC)Reply

Motor oil analysis edit

In the "Usage" section, in the paragraph beginning "ICP is used for motor oil analysis...", the term "ICP" was used throughout, without the "-MS". In my (considerable) experience, the ICP technique predominantly used in motor oil analysis is ICP-AES. Whilst ICP-MS is used, it is nowhere near as common and typically used in specialised analysis rather than routine engine oil sample testing. To qualify my experience, I have 18 years of product development and technical support with engine oils, including running a lubricating oil analytical laboratory. My final year project for my undergraduate degree was also in the subject of ICP-MS, specifically isolating and correcting for noise in the MS signal to improve detection limits and ion differentiation.

I have therefore moved the whole section to the ICP-AES article, with slight enhancements. Weasley one (talk) 09:37, 9 March 2011 (UTC)Reply

Question edit

In the opening paragraph, is "low-background isotope" synonymous with "minimally radioactive isotope"? — Preceding unsigned comment added by Thintommy (talkcontribs) 03:36, 26 March 2015 (UTC)Reply

External links modified edit

Hello fellow Wikipedians,

I have just modified one external link on Inductively coupled plasma mass spectrometry. Please take a moment to review my edit. If you have any questions, or need the bot to ignore the links, or the page altogether, please visit this simple FaQ for additional information. I made the following changes:

When you have finished reviewing my changes, you may follow the instructions on the template below to fix any issues with the URLs.

This message was posted before February 2018. After February 2018, "External links modified" talk page sections are no longer generated or monitored by InternetArchiveBot. No special action is required regarding these talk page notices, other than regular verification using the archive tool instructions below. Editors have permission to delete these "External links modified" talk page sections if they want to de-clutter talk pages, but see the RfC before doing mass systematic removals. This message is updated dynamically through the template {{source check}} (last update: 5 June 2024).

  • If you have discovered URLs which were erroneously considered dead by the bot, you can report them with this tool.
  • If you found an error with any archives or the URLs themselves, you can fix them with this tool.

Cheers.—InternetArchiveBot (Report bug) 13:27, 22 December 2017 (UTC)Reply

External links modified (January 2018) edit

Hello fellow Wikipedians,

I have just modified 2 external links on Inductively coupled plasma mass spectrometry. Please take a moment to review my edit. If you have any questions, or need the bot to ignore the links, or the page altogether, please visit this simple FaQ for additional information. I made the following changes:

When you have finished reviewing my changes, you may follow the instructions on the template below to fix any issues with the URLs.

This message was posted before February 2018. After February 2018, "External links modified" talk page sections are no longer generated or monitored by InternetArchiveBot. No special action is required regarding these talk page notices, other than regular verification using the archive tool instructions below. Editors have permission to delete these "External links modified" talk page sections if they want to de-clutter talk pages, but see the RfC before doing mass systematic removals. This message is updated dynamically through the template {{source check}} (last update: 5 June 2024).

  • If you have discovered URLs which were erroneously considered dead by the bot, you can report them with this tool.
  • If you found an error with any archives or the URLs themselves, you can fix them with this tool.

Cheers.—InternetArchiveBot (Report bug) 09:35, 22 January 2018 (UTC)Reply

warning about edits by Analytic Jena edit

IP address 82.119.177.151 belongs to analytik-jena.de. Any edits by this IP should be flagged as having a conflict of interest. In particular, I have tagged as "not in citation" the statement that "Analytik Jena ICP-MS PQMS is the most sensitive instrument on the market." Note that this statement is older than the edits by the Analytic Jena; it appears to have been added by the company's predecessor, Bruker. While the author may be knowledgable, they are too close to the topic at hand. 136.62.254.174 (talk) 02:45, 24 August 2018 (UTC)Reply

Exporting regulations from a determined country in the introduction? edit

I don't want to directly remove a cited paragraph, but i don't think that the sentence fits in the introduction of a characterization technique, any opinion on if it should be moved (where?) or removed?
Due to possible applications in nuclear technologies, ICP-MS hardware is a subject for special exporting regulations in the People's Republic of China.

--Bsckr (talk) 14:26, 5 October 2021 (UTC)Reply

@Bsckr: I would just delete it as insignificant, even though it's sourced. If we had a section on applications in nuclear technologies then maybe it could go there, but even then I would say it's marginal to include. –CWenger (^@) 14:46, 5 October 2021 (UTC)Reply
  Done I agree.--Bsckr (talk) 04:10, 6 October 2021 (UTC)Reply

Wiki Education assignment: Meso and Microfluidics in Chemical Analysis edit

  This article was the subject of a Wiki Education Foundation-supported course assignment, between 28 March 2022 and 3 June 2022. Further details are available on the course page. Student editor(s): Jndavis22 (article contribs).