Talk:Stress intensity factor

Latest comment: 5 years ago by 71.178.166.126 in topic This page is wrong in nomenclature
  • Can you transfer the image to commons, so every language wiki could use it? abakharev 09:27, 27 August 2005 (UTC)Reply
  • Is this image of the different modes of crack loading, from the equivalent Japanese page clearer? --Amgreen (talk) 07:42, 29 September 2010 (UTC)Reply
図1 荷重モード 開口形(モードI )、面内せん断形(モードII )、面外せん断形(モードIII )
図1 荷重モード
開口形(モードI )、面内せん断形(モードII )、面外せん断形(モードIII )
  • Amgreen: Yes, that one is much nicer :) Please insert that one, if it's possible! 193.11.155.128 (talk) 14:07, 12 October 2010 (UTC)Reply

Crack tip radius goes towards zero. edit

The sentence: "This relation breaks down very close to the tip (small  ) because as   goes to 0, the stress   goes to  ." might be correct in a mathematical sense, but in reality a crack wouldn't be much smaller than the size of an atom, wouldn't it? And then one still has normally "blunt" cracks which are probably ways broader at the tip than one atom. Peterthewall (talk) 11:23, 27 February 2013 (UTC)Reply

Examples, Uniform uniaxial stress, crack unsymmetrically edit

"If the crack is not located centrally along the width, i.e.,  , the stress intensity factor at location A has the form

 

where the factors   can be found in tabulated form for various values of  . A similar expression can be found for tip B of the crack."

This is of exactly NO help at all!
It does NOT "have" this form. It can be "approximated" (quite well, I guess) by this form - given that one is in the possession of the 20  s. But as these are not given here + no reference to them, then this formulae is as helpful as saying "...it takes a form that Google knows. Good luck.".
A real analytical solution can be found in Kathiresan 1984, freely available here: http://oai.dtic.mil/oai/oai?verb=getRecord&metadataPrefix=html&identifier=ADA150420
Scroll down to case 26 on p 175 and combine it with case 11 on p 172. This should do. I don't have the 20 minutes at the moment to type in these formulae, unfortunately. Peterthewall (talk) 15:07, 16 April 2013 (UTC)Reply
Thanks, Bbanerje for including all this! Peterthewall (talk) 13:44, 19 April 2013 (UTC)Reply

This page is wrong in nomenclature edit

The stress intensity factor is non-sensical term. "Factor" implies a scalar multiple to a variable. This is not a unit-less entity.

What this page is describing is the STRESS INTENSITY.

The stress intensity is the stress CONCENTRATION factor PLUS the applied stress. — Preceding unsigned comment added by 71.178.166.126 (talk) 21:24, 22 September 2018 (UTC)Reply