This drawing is intended to illustrate common guidelines for the forming of through-penetrations such that proper sizing and costing for firestops can occur. In the case of sleeving, which is limited to fire-separations made of concrete and masonry, the mechanical and electrical trades are responsible for the sizing of the openings because they apply the sleeves. In the case of drywall fire separations, the opening size is determined by the drywall contractor, unless the mechanical and electrical trades are contractually obliged to provide sleeving here as well, with proper fastening methods that must be subject to bounding. All trades shall can use this guideline. This permits accurate priceing as well as accountability for field variances. Exceptions are penetrations in timber floors. Often, timber floor openings are simply cut by means of a chainsaw. In this case, the width of the blade will determine sizes. Sizing of all openings has significant impact upon bounding. Therefore, communication between all affected trades is of great importance before any openings are made.
to share – to copy, distribute and transmit the work
to remix – to adapt the work
Under the following conditions:
attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.
This diagram image could be re-created using vector graphics as an SVG file. This has several advantages; see Commons:Media for cleanup for more information. If an SVG form of this image is available, please upload it and afterwards replace this template with {{vector version available|new image name}}.
It is recommended to name the SVG file “Penetration sizing.svg”—then the template Vector version available (or Vva) does not need the new image name parameter.
This diagram image was uploaded in the JPEG format even though it consists of non-photographic data. This information could be stored more efficiently or accurately in the PNG or SVG format. If possible, please upload a PNG or SVG version of this image without compression artifacts, derived from a non-JPEG source (or with existing artifacts removed). After doing so, please tag the JPEG version with {{Superseded|NewImage.ext}} and remove this tag. This tag should not be applied to photographs or scans. If this image is a diagram or other image suitable for vectorisation, please tag this image with {{Convert to SVG}} instead of {{BadJPEG}}. If not suitable for vectorisation, use {{Convert to PNG}}. For more information, see {{BadJPEG}}.
Captions
Add a one-line explanation of what this file represents
{{Information |Description=This drawing is intended to illustrate common guidelines for the forming of through-penetrations such that proper sizing and costing for firestops can occur. In the case of sleeving, which is limited to fire-separations made
File usage
No pages on the English Wikipedia use this file (pages on other projects are not listed).
Metadata
This file contains additional information, probably added from the digital camera or scanner used to create or digitize it.
If the file has been modified from its original state, some details may not fully reflect the modified file.